A randomized controlled trial investigating the effect of thermal steam spray on nasal condition, neurological function, and sleep quality in young adults with nasal congestion and irregular sleep patterns.
BMC pulmonary medicine · 2026
Abstract originale
BACKGROUND: Intranasal thermal steam spray (ITSS) has been suggested to relieve nasal stuffiness and improve sleep-related symptoms. However, its mechanistic effects on respiratory capacity, neurological functions, including autonomic nervous system (ANS) and brain activities, remain underexplored. Therefore, this study aimed to investigate the effects of an ITSS intervention on nasal condition, respiratory and neurological functions, and sleep quality in young adults with nasal congestion and irregular sleep patterns. METHODS: Sixty university students (aged 20-26 years) with an average duration of nasal congestion and sleep irregularity of over three years participated. Two dormitories were randomly assigned to either a control group (CON; n = 30) or an intervention group (ITSS; n = 30). The ITSS device, delivering 43 °C thermal wet steam using jet stream (80 mm H₂O) technology, was administered for 15 min, 3 times per week, 30 min before bedtime for 8 weeks. RESULTS: After the intervention, subjective nasal congestion and sleep conditions deteriorated in the CON but improved in the ITSS (p < 0.001). Pulmonary outcomes, including reduced respiratory rate (p < 0.001) and increased FEV₁ (p < 0.001) and PEF (p < 0.001), improved only in the ITSS. Heart rate variability and blood pressure indices also showed favourable changes. Electroencephalographic analysis revealed increased wide band, alpha, and gamma powers in the ITSS, contrasting with declines in the CON (p < 0.05). In the ITSS group, PSQI-K components improved, with daytime dysfunction reduced by 32.78 ± 41.40% (p < 0.001). Total PSQI-K scores rose in the CON group (+ 14.64 ± 22.44%) but declined in the ITSS group (- 38.90 ± 21.99%), showing a significant difference (p < 0.001). CONCLUSIONS: These findings suggest that ITSS enhances airflow by humidifying the nasal environment, thereby facilitating respiratory function and stabilizing ANS activity and brain function. This process ultimately contributes to improved overall sleep quality in young adults experiencing nasal congestion and irregular sleep patterns. TRIAL REGISTRATION: The study was retrospectively registered on April 3, 2025, in the Clinical Research Information Service ( https://cris.nih.go.kr/cris/search/listDetail.do/ ) under registration number KCT0010381.
Parole chiave
Leggi il testo integrale originale
Testo estratto dalla pubblicazione: sono esclusi immagini, media, supplementi e parti soggette a diritti distinti.
A randomized controlled trial investigating the effect of thermal steam spray on nasal condition, neurological function, and sleep quality in young adults with nasal congestion and irregular sleep patterns
Background
Intranasal thermal steam spray (ITSS) has been suggested to relieve nasal stuffiness and improve sleep-related symptoms. However, its mechanistic effects on respiratory capacity, neurological functions, including autonomic nervous system (ANS) and brain activities, remain underexplored. Therefore, this study aimed to investigate the effects of an ITSS intervention on nasal condition, respiratory and neurological functions, and sleep quality in young adults with nasal congestion and irregular sleep patterns.
Methods
Sixty university students (aged 20–26 years) with an average duration of nasal congestion and sleep irregularity of over three years participated. Two dormitories were randomly assigned to either a control group (CON; n = 30) or an intervention group (ITSS; n = 30). The ITSS device, delivering 43 °C thermal wet steam using jet stream (80 mm H₂O) technology, was administered for 15 min, 3 times per week, 30 min before bedtime for 8 weeks.
Results
After the intervention, subjective nasal congestion and sleep conditions deteriorated in the CON but improved in the ITSS (p < 0.001). Pulmonary outcomes, including reduced respiratory rate (p < 0.001) and increased FEV₁ (p < 0.001) and PEF (p < 0.001), improved only in the ITSS. Heart rate variability and blood pressure indices also showed favourable changes. Electroencephalographic analysis revealed increased wide band, alpha, and gamma powers in the ITSS, contrasting with declines in the CON (p < 0.05). In the ITSS group, PSQI-K components improved, with daytime dysfunction reduced by 32.78 ± 41.40% (p < 0.001). Total PSQI-K scores rose in the CON group (+ 14.64 ± 22.44%) but declined in the ITSS group (− 38.90 ± 21.99%), showing a significant difference (p < 0.001).
Conclusions
These findings suggest that ITSS enhances airflow by humidifying the nasal environment, thereby facilitating respiratory function and stabilizing ANS activity and brain function. This process ultimately contributes to improved overall sleep quality in young adults experiencing nasal congestion and irregular sleep patterns.
Trial registration
The study was retrospectively registered on April 3, 2025, in the Clinical Research Information Service (https://cris.nih.go.kr/cris/search/listDetail.do/) under registration number KCT0010381.
Supplementary Information
The online version contains supplementary material available at https://doi.org/10.1186/s12890-026-04585-5.
Background
Respiration is an essential life-sustaining activity that delivers oxygen to all cells of the human body, enabling normal physiological functions. While breathing can occur through both the nasal and oral cavities, the nose is the primary organ responsible for respiratory capacity [1]. The respiratory system comprises from nasal cavity to lungs, facilitating oxygen intake through the nasal passages and its circulation throughout the body via alveoli in the lungs [2]. For efficient respiration, the intranasal airway must remain unobstructed [3]. However, various conditions such as nasal septal deviation, colds, sinusitis, and allergic rhinitis can lead to nasal congestion or obstruction [4]. Nasal congestion including abnormal rhinitis or can compromise nasal respiratory function, thereby disrupting the sleep–wake cycle [5]. Such impairment has been associated with various sleep disorders, including insomnia, hypersomnia, and so on [6]. Irregular sleep patterns—especially those linked to nasal dysfunction—have been shown to impair respiratory function and are further associated with elevated stress levels, increased fatigue, and declines even in cognitive performance and concentration [7]. Especially, nasal obstruction may influence autonomic nervous system (ANS) regulation by increasing upper airway resistance and altering breathing patterns [8]. Increased respiratory effort and impaired nasal airflow have been associated with sympathetic activation and reduced parasympathetic modulation, resulting in alterations in heart rate variability (HRV) and cardiovascular regulation [9]. Consequently, respiratory function, blood pressure (BP), and HRV represent complementary physiological indicators that may reflect changes in autonomic regulation associated with improvements in the nasal environment [10]. Ultimately, maintaining an intranasal airway is a crucial factor in ensuring a high quality of life, sleep quality, and overall health [11, 12].
Previous studies have investigated conservative approaches for improving the nasal environment, including nasal irrigation and conventional steam inhalation [13–15]. Although these methods are safe and inexpensive, conventional steam inhalation often requires preparation of heated water or external steam-generating equipment and may provide inconsistent steam temperature and exposure conditions [16]. In contrast, the investigational intranasal thermal steam spray device (ITSS) used in the present study is a portable, temperature-controlled system designed to deliver warm humidified steam directly into the nasal cavity under standardized operating conditions. The present study was therefore designed to evaluate whether these practical design characteristics are associated with improvements in nasal condition, respiratory function, neurological function, and sleep quality. This home medical device has been reported to provide a safe and effective solution for nasal congestion by delivering moist steam at 43 °C into the nasal cavity [17]. However, despite its demonstrated effectiveness in alleviating intranasal congestion, no studies to date have explored its potential impact on respiratory capacity and sleep quality. In particular, there is a significant lack of research investigating whether the flow of air circulating through an optimal respiratory pathway influences the ANS regulation and, in turn, affects stable brain activity. Therefore, the primary objective of the present randomized controlled trial was to determine whether improving the nasal environment through ITSS could enhance sleep quality in young adults with nasal congestion and irregular sleep patterns. A secondary objective was to investigate potential physiological mechanisms underlying these effects by evaluating respiratory function, ANS activity, and electroencephalographic responses.
Materials and methods
Study design
This study was designed as a randomized, double-blinded, sham-controlled trial. Following approval by the Hanseo University Institutional Review Board (HS24-12-18), the study investigated the efficacy of ITSS through an interventional approach. Participants underwent an 8-week ITSS intervention (April 7 to June 2, 2025), followed by assessments and analyses of its impact on subjective nasal congestion, perceived sleep condition, respiratory performance, neurological function including ANS and brain activities, and overall sleep quality. To preserve participant blinding, the active and sham devices were identical in external appearance, weight, indicator lights, operating sound, and handling procedures. They were informed only that two different versions of the investigational device were being compared and were not informed which device represented the active intervention. All intervention sessions were conducted individually, and participants were instructed not to discuss their experiences with other participants throughout the study period. Outcome assessors and data analysts remained blinded to group allocation until completion of the statistical analyses. This study obtained written informed consent in accordance with the Declaration of Helsinki [18] and was retrospectively registered with the Clinical Research Information Service, Republic of Korea (registration number: KCT0010381) on April 3, 2025. The trial was registered retrospectively because of an administrative oversight in the timing of registration. Importantly, the study protocol, eligibility criteria, intervention procedures, outcome measures, and statistical analysis plan had been finalized before participant enrolment, and no protocol modifications were made as a result of the delayed registration. This study adhered to the CONSORT guidelines published in 2025 [19], and the completed checklist is provided in the supplementary materials (Supplementary file 1).
Participants
The participants were male and female university students aged between 20 and 26 years, residing in two dormitories on the same university campus. They expressed interest in the study after viewing a social media advertisement related to the research, reporting symptoms of nasal congestion and sleep disturbances. Participants were instructed to carry out their daily activities and meals within their assigned dormitories and were asked not to disclose their involvement in the study to others. The inclusion criteria for this study required participants to exhibit symptoms such as clear nasal discharge, sneezing, nasal congestion, and nasal itching, along with irregular sleep patterns. Participants were assessed to determine whether their symptoms were occasional or persistent and to identify periods of symptom exacerbation. Subsequently, an otolaryngologist conducted a diagnostic evaluation for rhinitis, including nasal examination and nasal secretion analysis. Meanwhile, individuals diagnosed with congenital nasal obstruction, such as congenital pyriform aperture stenosis, or those with chronic diseases affecting the heart, lungs, or other major organs were excluded from this study. Additionally, individuals who had been regularly participating in an exercise program for more than six months, were heavy smokers, engaged in high-risk alcohol consumption as defined by the WHO, or had metabolic syndrome were also excluded [20]. Individuals with a prior diagnosis of cardiovascular or cerebrovascular disease, cancer, or psychiatric conditions were likewise excluded from the study. The sample size was estimated using G*Power version 3.1.9.7 (Heinrich-Heine-Universität, Düsseldorf, Germany) for a repeated-measures design involving two groups and two measurement occasions [21]. Assuming a medium group-by-time interaction effect, an α level of 0.05, and a statistical power of 0.95, the minimum required sample size was estimated to be 54 participants. This calculation was based on the overall repeated-measures design rather than on an outcome-specific effect estimate. Therefore, the study was not necessarily powered to detect effects across all secondary and mechanistic outcomes, and these findings should be interpreted accordingly.
As shown in Fig. 1, a total of 68 participants were recruited; however, 4 were excluded because they failed to meet the inclusion criteria or for personal reasons. Among the remaining 64 participants who completed the demographic survey and baseline assessment, random tags were used to assign one facility to the control group (CON) and another facility to the ITSS group. The principal investigator carried out all these procedures. A total of 32 participants were assigned to the CON at one facility, while another 32 participants were allocated to the ITSS group at a separate facility. During the eight-week program, two participants from the CON and two participants from the ITSS group dropped out during the follow-up stage. No participants from either group were excluded during the analysis, resulting in a final sample of 30 participants in each group: the CON and the ITSS group. Standardized guidelines were implemented for pre- and post-assessments to ensure strict blinding throughout the study.
ITSS intervention program
An intranasal vapor spray device (RhinoCare Korea Inc., Gumi, Korea) is a medical device certified by the Ministry of Food and Drug Safety for the treatment of nasal congestion caused by rhinitis, sinusitis, colds, and flu. This device facilitates breathing by utilizing Jet Stream technology (80 mmH₂O), which delivers 43 °C vapor heat to the intranasal cavity through an internal heating mechanism, and its effectiveness has been recognized. Additionally, it has met safety standards for medical devices, including the residual wave test, as verified by an authorized testing agency [17]. Participants in the ITSS group were instructed to use the device for 15 min, three times per week, for eight weeks, activating it 30 min before bedtime. Meanwhile, participants in the CON were provided with the device without vapor heat emission and were instructed to use it under the same conditions as the ITSS group.
Outcome measures
The primary outcome was sleep quality, evaluated using the Pittsburgh Sleep Quality Index–Korean version (PSQI-K). Secondary outcomes included subjective nasal congestion, respiratory function, BP, ANS activity assessed by HRV, and electroencephalographic parameters. These secondary outcomes were selected to explore potential physiological mechanisms linking improvement of the nasal environment to changes in sleep quality. Meanwhile, body composition and dietary intake were assessed to characterize the study population and to monitor potential confounding factors throughout the intervention period. Because nutritional intake, body composition, and obesity-related characteristics may influence respiratory function, nasal symptoms, and sleep quality, these variables were monitored to confirm baseline comparability and to minimize the potential influence of non-intervention-related factors on the study outcomes.
Anthropometric data
These measurements were conducted on the first and final days of the intervention between 7:00 a.m. and 8:00 a.m., prior to breakfast. To ensure measurement accuracy, assessments were performed on participants who had refrained from fluid intake and had completed both urination and defecation beforehand. Height was measured using an automated stadiometer. Body weight, fat mass, and muscle mass were assessed using the InBody 720 device (BioSpace, Seoul, Korea) with participants standing after a 10-hour fasting period. Body mass index (BMI) was also calculated based on the weight-to-height ratio.
Clinical data
To monitor external variables, participants were asked to complete a questionnaire between 9:00 p.m. and 10:00 p.m. each night prior to sleep, recording dietary intake and daily activities. In addition, between 7:00 a.m. and 8:00 a.m. each morning, the degree of subjective nasal openness and perceived post-sleep condition were assessed using a visual analogue scale (VAS). First, all participants in both groups consumed three meals per day, prepared under the supervision of a certified nutritionist. To ensure accurate dietary assessment and monitor adherence throughout the intervention, participants’ daily food intake was documented by a researcher using an AI-assisted dietary camera system (DoingLab Inc., Seoul, Korea) [22]. (Supplementary file 2). Second, physical activity (PA) levels were assessed using the International PA Questionnaire-Short Form [23] (Supplementary file 3). Third, all participants were instructed to evaluate the subjectively felt degree of nasal congestion and their post-sleep condition each morning upon waking, using a VAS-based recording sheet delivered via direct message. The perceived degree of nasal dilatation was determined using a VAS [24]. The left end of a 10 cm long line was placed as ‘open nasal cavity (0)’ and the right end was placed as ‘blocked nasal cavity (10)’, and they were asked to mark the degree of nasal congestion they felt. The left end of a 10 cm long line was placed as ‘no discomfort with sleep (0)’ and ‘severe discomfort with sleep (10)’, and they were asked to mark the sleep problems he or she felt. The collected data were analysed on a weekly and monthly basis.
Respiratory capacity, blood pressure and heart rate variability
Respiratory capacity, BP, and HRV used to assess ANS function was measured between 7:00 a.m. and 8:00 a.m. on the first and final days of the intervention. First, resting respiratory rate was assessed by observing chest movement while participants lay in a supine position on a bed for 60 s. Subsequently, pulmonary function was evaluated using a Spirovit SP-1 spirometer (SCHILLER AG, Switzerland). Key respiratory variables measured included forced expiratory volume in one second (FEV₁) and peak expiratory flow (PEF). For testing, participants wore a nasal clip to prevent air leakage and inserted a disposable mouthpiece into their mouths. They were instructed to exhale forcefully through the mouth following a maximal inhalation to measure the targeted respiratory parameters. Prior to the actual data collection, participants underwent practice sessions to familiarize themselves with the spirometry technique. Each participant performed the test three times, and the highest value recorded among the trials was used for statistical analysis [25]. Second, resting BP was measured using an automated sphygmomanometer. For the assessment, an appropriately sized cuff was placed on the brachial artery of the right arm. Third, to assess ANS activity, HRV was measured using the uBiomacpa device (Biosensecreative Co. Ltd. Seoul, Korea). The measurements were taken twice on the day of the experiment, and the average values were used for analysis [26–29]. During the measurement, participants sat comfortably for 2–3 min while pulse waves were non-invasively recorded via a sensor attached to the index finger. To ensure data reliability, participants were advised to remain still and avoid talking, coughing, or deep breathing during the procedure. The analysis included both time-domain measures and frequency-domain parameters derived from power spectral density estimates using autoregressive modeling [30]. In time-domain analysis, HRV is assessed by measuring the intervals between successive normal QRS complexes, referred to as normal-to-normal (NN) intervals. Two key time-domain metrics are used: the standard deviation of NN intervals (SDNN), which reflects overall HRV by capturing all cyclic components, and the root mean square of successive differences between NN intervals (RMSSD), which primarily reflects parasympathetic activity. In contrast, frequency-domain analysis examines the spectral components of HRV. This includes low-frequency (LF) and high-frequency (HF) bands, which are associated with sympathetic and parasympathetic nervous system activity, respectively. The LF/HF ratio, calculated from normalized LF and HF values, served as an index of sympathetic modulation [31]. To enhance data accuracy, the first hour of recording was excluded from analysis [26], and any transient noise or movement artifacts were manually removed.
Electroencephalogram data measures
Prior to electroencephalography (EEG) acquisition, participants underwent a 10-min resting period in a quiet and thermally controlled indoor environment to ensure physiological stabilization. Subsequently, resting EEG was recorded for 5 min while participants remained seated in a relaxed posture with their eyes gently closed [32, 33]. EEG data were acquired using a 10-channel wired EEG system (Neurofeedback Intermediate System, Montreal, Quebec, Canada). Scalp electrodes were affixed according to the international 10–20 system, targeting the frontal (F3, F4, Fz), temporal (T3, T4), parietal (P3, P4), and central regions. Reference electrodes were attached via ear clips on both earlobes. The sampling rate was configured at 500 Hz. Signal preprocessing included the application of a 60 Hz notch filter to remove power line interference and a bandpass filter to attenuate low- and high-frequency noise. Ocular artifacts were eliminated using Independent Component Analysis. Power spectral analysis was subsequently performed using Fast Fourier Transform, yielding absolute and relative power values across predefined frequency bands. To investigate the potential effects of nasal congestion on alterations in sleep-related EEG patterns, spectral power was examined across the entire brain in the wide band range and within specific frequency domains: delta (0.5–4 Hz; relative power: 0–20%), theta (4–8 Hz; 5–20%), alpha (8–12 Hz; 20–40%), beta (13–30 Hz; 10–30%), and gamma (> 30 Hz; 3–10%) [34]. Furthermore, to enable a more refined assessment of neural activity, the alpha / beta ratio (ABR) and theta / beta ratio (TBR) were computed and analyzed.
Sleep quality measures
The Pittsburgh Sleep Quality Index (PSQI) is a standardized self-report questionnaire designed to assess sleep quality and patterns over the past month. It is widely utilized in clinical and research settings to evaluate sleep disturbances and insomnia. Originally developed by Buysse et al. [35], the PSQI has been adapted into various languages, including Korean. This study employed the Korean version of the PSQI (PSQI-K), which comprises 18 items across seven domains: subjective sleep quality (1 item), sleep latency (2 items), sleep duration (1 item), sleep efficiency (2 items), sleep disturbances (9 items), use of sleep medication (1 item), and daytime dysfunction (2 items). The PSQI-K has demonstrated high reliability, with a Cronbach’s α of 0.779. Each domain is scored on a scale of 0 to 3, yielding a total score ranging from 0 to 21, where higher scores indicate poorer sleep quality. In this study, sleep quality was classified based on the criteria established by Shon et al. [36]. A PSQI-K total score of 8.5 points or lower was categorized as “good sleep quality,” while a score exceeding 8.5 points was classified as “poor sleep quality.”
Statistical analysis
Statistical analyses were performed using GraphPad Prism 10.4.1 software (GraphPad Software, Boston, MA, USA). Descriptive statistics, including the mean and standard deviation (SD) of all data, were calculated. The normality of variable distribution was assessed using the Kolmogorov-Smirnov test. Categorical variables were expressed as frequencies and percentages and analysed using appropriate statistical tests. To examine baseline differences prior to the main analysis, the Mann–Whitney U test was employed for non-parametric pre-intervention variables. For normally distributed data, a two-way repeated measures ANOVA (2 × 2) was conducted to assess group and time interactions. In cases of non-normally distributed data, between-group comparisons were performed using the Mann–Whitney U test, while within-group comparisons were assessed using the Wilcoxon signed-rank test. Because each outcome variable represented a prespecified physiological or clinical endpoint, statistical analyses were performed separately for each outcome. The primary interpretation focused on the group × time interaction rather than multiple pairwise comparisons. Percentage change (Δ%) was calculated to evaluate detailed variations at each time point. Effect sizes (η²) for the two groups were interpreted based on the thresholds proposed by Fritz et al. [37], with values < 0.10 considered small, 0.42 as medium, and 0.80 as large. The statistical significance level was set at p ≤ 0.05.
Results
Demographic and clinical factors’ characteristics
A total of 60 participants were randomly assigned to either the sham CON (males, n = 15; females, n = 15) or the ITSS group (males, n = 16; females, n = 14). The mean age of all participants was 22.27 ± 1.80 years, with an average height of 165.16 ± 9.03 cm, body weight of 68.82 ± 13.94 kg, and BMI of 24.98 ± 3.11 kg/m². All participants had the average durations of nasal congestion and irregular sleep pattern of 3.39 ± 0.74 years and 3.01 ± 0.77 years. Prior to the experiment, there were no significant differences between the groups in terms of age, sex, height, body composition, smoking status, and alcohol consumption. No significant differences were found between the groups regarding the durations of nasal congestion and irregular sleep duration. The pre-experiment characteristics of the two groups are presented in Table 1.
Table 1Differences in demographic and clinical characteristics at baseline
Groups
CON ITSS
Items mean SD mean SD Z p η²
Age (y) 22.03 1.79 22.50 1.81 -1.023 0.307 0.017
Sex 1.50 0.51 1.47 0.51 -0.256 0.798 0.001
Height (cm) 163.91 9.39 166.41 8.63 -1.089 0.276 0.020
Weight (kg) 68.10 14.42 69.53 13.65 -0.459 0.646 0.003
Muscle mass (kg) 29.12 6.65 28.74 6.74 -0.067 0.947 0.001
Fat mass (kg) 19.98 5.00 20.50 5.99 -0.319 0.750 0.002
Percent fat (%) 30.61 10.09 30.47 10.23 -0.237 0.813 0.000
Body mass index (kg/m²) 25.09 3.31 24.88 2.95 -0.200 0.842 0.001
Basal metabolic rate (kcal) 1454.27 272.35 1466.00 251.51 -0.438 0.661 0.001
Smoking 1.47 0.51 1.43 0.50 -0.257 0.797 0.001
Alcohol 1.73 0.45 1.80 0.41 -0.605 0.545 0.006
Nasal congestion (y) 3.33 0.80 3.44 0.68 -1.093 0.275 0.006
Sleep irregularity (y) 2.98 0.73 3.03 0.82 -0.074 0.941 0.001
All data are presented as mean and standard deviation (SD). Sex was coded as male = 1 and female = 2, smoking status as smoker = 1 and non-smoker = 2, and alcohol consumption as drinker = 1 and non-drinker = 2 for analysis. CON control, ITSS intranasal thermal steam spray
Among the controlled variables, prior to the experiment, the dietary intake was 2251.73 ± 149.87 kcal for the CON and 2221.20 ± 164.69 kcal for the ITSS group, with no significant difference between the two groups (p = 0.630, η² = 0.010). After the experiment, the dietary intake measured 2380.80 ± 281.42 kcal in the CON and 2350.33 ± 219.76 kcal in the ITSS group, again showing no significant difference (p = 0.589, η² = 0.004). Similarly, before the experiment, the PA levels were 1814.53 ± 335.39 MET·min/ week for the CON and 1917.60 ± 360.07 MET·min/week for the ITSS group, with no significant difference (p = 0.294, η² = 0.022). After the experiment, the PA levels were recorded as 1730.40 ± 289.26 MET·min/week in the CON and 1750.43 ± 274.50 MET·min/week in the ITSS group, also showing no significant difference (p = 0.620, η² = 0.001). Meanwhile, throughout the 8-week intervention period, participants were monitored for potential adverse events, including nasal irritation, discomfort, excessive heat sensation, epistaxis, dizziness, and other unexpected symptoms following device use. No serious adverse events, treatment-related complications, or withdrawals attributable to the intervention were observed. All participants tolerated the intervention well, and no participant discontinued the study because of discomfort associated with the device.
Influence of the ITSS intervention on subjectively felt nasal congestion and sleep state
According to Table 2, no significant difference was observed between the two groups in the perceived level of nasal congestion prior to the intervention. Following the intervention, the CON exhibited an increase in perceived nasal congestion, whereas the ITSS group showed a decrease, yielding significant differences between groups, within groups, and in the interaction. The perceived sleep condition upon awakening showed no significant difference between the two groups before the intervention. Following the intervention, however, the CON demonstrated an increase in perceived sleep condition, while the ITSS group reported a decrease, leading to significant effects between groups, within groups, and in the interaction effect.
Table 2Comparative results of subjective nasal congestion and sleep condition
Groups (G)
Control ITSS p(η²)
Items Time (T) mean SD mean SD G T G×T
Nasal congestion Pre 4.81 0.98 4.93 0.97 0.001 0.004 0.001
Post 5.22 0.73 3.55 1.21 (0.213) (0.133) (0.344)
Sleep condition Pre 4.64 1.79 4.77 1.53 0.016 0.006 0.001
Post 4.93 0.89 3.36 0.99 (0.096) (0.123) (0.243)
All data are presented as mean and standard deviation (SD). CON control, ITSS intranasal thermal steam spray
As illustrated in Fig. 2, changes in perceived nasal congestion and sleep condition following the intervention differed significantly between the groups. In the CON, nasal congestion increased by 11.92 ± 22.28%, whereas it decreased by -25.55 ± 28.74% in the ITSS group, showing a significant difference between the groups (Fig. 2A). Similarly, subjective sleep condition increased by 18.88 ± 39.59% in the CON but declined by -24.22 ± 28.03% in the ITSS group, resulting in a statistically significant difference (Fig. 2B).
Influence of the ITSS intervention on respiratory capacity and BP
As observed in Table 3, there was no significant difference in resting respiratory rate between the two groups prior to the intervention. However, after the intervention, the resting respiratory rate increased in the CON but decreased in the ITSS group, resulting in a significant interaction effect. Similarly, no significant differences were observed between the groups in FEV₁ and PEF before the intervention. Following the intervention, however, both FEV₁ and PEF decreased in the CON but increased in the ITSS group, yielding statistically significant interaction effects. As further observed in Table 3, there were no significant differences in systolic blood pressure (SBP) and diastolic blood pressure (DBP) between the groups before the intervention. However, after the intervention, SBP and DBP increased in the CON but decreased in the ITSS group, resulting in significant interaction effects.
Table 3Comparative results of respiratory capacity and blood pressure
Groups (G)
CON ITSS p(η²)
Items Time (T) mean SD mean SD G T G×T
Respiratory capacity
rRR (reps/min) Pre 17.13 3.18 17.70 3.27 0.055 0.793 0.001
Post 18.90 2.43 15.67 4.05 (0.062) (0.001) (0.196)
FEV₁ (L) Pre 3.20 0.68 3.26 0.75 0.031 0.212 0.001
Post 2.95 0.66 3.66 0.76 (0.078) (0.027) (0.320)
PEF (L/s) Pre 4.08 1.24 4.05 0.73 0.061 0.002 0.001
Post 3.89 1.27 4.97 1.26 (0.059) (0.159) (0.298)
Blood pressure level
SBP (mmHg) Pre 131.47 11.04 132.77 10.03 0.053 0.835 0.001
Post 137.30 12.76 126.40 8.16 (0.063) (0.001) (0.283)
DBP (mmHg) Pre 74.57 9.29 76.20 10.89 0.771 0.315 0.036
Post 75.77 9.03 72.87 7.63 (0.001) (0.017) (0.074)
All data are presented as mean and standard deviation (SD). CON control, ITSS intranasal thermal steam spray, rRR resting respiratory rate, FEV₁ forced expiratory volume in 1s, PEF peak expiratory flow, SBP systolic blood pressure, DBP diastolic blood pressure
As illustrated in Fig. 3, the changes in respiratory capacity and BP levels after the intervention revealed significant differences between the groups. The resting respiratory rate increased by 12.39 ± 16.70% in the CON, while it decreased by -8.64 ± 28.56% in the ITSS group, indicating a significant between-group difference (Fig. 3A). Regarding pulmonary function, FEV₁ decreased by -6.98 ± 12.69% in the CON but increased by 14.29 ± 19.54% in the ITSS group (Fig. 3B). Similarly, PEF declined by -3.99 ± 14.55% in the CON but rose by 23.80 ± 27.60% in the ITSS group (Fig. 3C), both showing significant differences between the groups. As for BP, SBP increased by 4.58 ± 7.10% in the CON, whereas it decreased by -4.44 ± 7.38% in the ITSS group (Fig. 3D). DBP increased by 2.11 ± 9.66% in the CON and by -3.35 ± 10.60% in the ITSS group (Fig. 3E), both also showing significant differences between the groups. These findings suggest that the application of ITSS may have a beneficial effect on cardiopulmonary function.
Influence of the ITSS intervention on HRV
As shown in Table 4, the HR, a time-domain index of HRV, did not differ significantly between the two groups before the intervention. However, after the intervention, HR increased in the CON but decreased in the ITSS group, resulting in a significant interaction effect. SDNN also showed no significant difference between the two groups prior to the intervention. After the intervention, both groups exhibited a decreasing trend, but the CON demonstrated a more pronounced decline compared to the ITSS group, leading to significant differences within groups and in the interaction effect. Meanwhile, RMSSD did not significantly differ between the groups before the intervention. After the intervention, however, RMSSD decreased in the CON and increased in the ITSS group, showing significant differences between groups and in the interaction effect. As further shown in Table 4, the frequency-domain indices of HRV, namely LF and the LF/HF ratio, did not show significant differences between the two groups before the intervention. However, after the intervention, both LF and the LF/HF ratio increased in the CON but decreased in the ITSS group, resulting in significant between-group and interaction effects. Meanwhile, HF also showed no significant difference between the groups prior to the intervention. After the intervention, however, HF decreased in the CON and increased in the ITSS group, yielding statistically significant differences between groups, within groups, and in the interaction effect.
Table 4Comparative results of HRV
Groups (G)
CON ITSS p(η²)
Items Time (T) mean SD mean SD G T G×T
Time domain of heart rate variability
HR (bpm) Pre 76.57 11.33 75.33 14.88 0.071 0.143 0.001
Post 79.00 10.25 69.83 9.44 (0.055) (0.037) (0.203)
SDNN (ms) Pre 73.37 37.57 69.22 31.30 0.351 0.001 0.041
Post 41.69 14.05 56.63 24.76 (0.015) (0.291) (0.071)
RMSSD (ms) Pre 35.53 10.98 36.53 11.99 0.013 0.665 0.001
Post 30.18 11.71 43.01 11.45 (0.103) (0.003) (0.267)
Frequency domain of heart rate variability
LF (ms²) Pre 657.17 98.57 663.17 109.65 0.031 0.315 0.001
Post 697.70 116.14 592.37 90.57 (0.078) (0.017) (0.194)
HF (ms²) Pre 711.97 155.93 713.33 127.96 0.001 0.001 0.001
Post 543.37 163.60 771.07 104.90 (0.174) (0.187) (0.489)
LF/HF ratio Pre 2.40 0.83 2.36 1.05 0.001 0.001 0.001
Post 2.70 0.79 0.78 0.17 (0.363) (0.372) (0.563)
All data are presented as mean and standard deviation (SD). CON control, ITSS intranasal thermal steam spray, SBP systolic blood pressure, DBP diastolic blood pressure, HR heart rate, SDNN standard deviation of NN intervals, RMSSD root mean square of successive differences, LF low frequency, HF high frequency, ANS autonomic nervous system
As illustrated in Fig. 4, HR increased by 3.82 ± 8.67% in the CON but decreased by -5.83 ± 10.09% in the ITSS group, resulting in a significant difference (Fig. 4A). Although SDNN decreased by -26.29 ± 49.35% in the CON and by -2.17 ± 56.74% in the ITSS group, this difference was not statistically significant (Fig. 4B). In contrast, RMSSD declined by -13.38 ± 24.29% in the CON but increased by 25.75 ± 39.49% in the ITSS group, showing a significant difference between the groups (Fig. 4C). LF power increased by 7.67 ± 19.22% in the CON and decreased by -9.15 ± 15.35% in the ITSS group, yielding a significant difference (Fig. 4D). HF power decreased by -23.12 ± 15.30% in the CON but increased by 10.37 ± 18.19% in the ITSS group, also showing a significant difference (Fig. 4E). Lastly, the LF/HF ratio rose by 18.47 ± 28.77% in the CON but dropped by -58.17 ± 22.02% in the ITSS group, resulting in a statistically significant difference (Fig. 4F).
Influence of the ITSS intervention on EEG factors
As presented in Table 5, following the intervention, the wide band mean increased in the CON but decreased in the ITSS group, resulting in a significant interaction effect. Although no statistically significant post-intervention differences were observed in delta, theta, beta, or other wave ratios, alpha power decreased in the CON but increased in the ITSS group, showing a significant interaction effect (p = 0.023). Similarly, Gamma power showed a greater increase in the ITSS group compared to the CON after the intervention, indicating a significant interaction effect (p = 0.038).
Table 5Comparative results of EEG factors
Groups (G)
CON ITSS p(η²)
Waves/Power Time (T) mean SD mean SD G T G×T
Wide band (µV²) Pre 29.16 12.08 30.33 9.29 0.112 0.852 0.001
Post 33.80 9.76 25.20 9.72 (0.043) (0.001) (0.192)
Delta Pre 14.30 4.12 14.23 3.51 0.071 0.025 0.224
Post 10.61 3.85 13.11 6.90 (0.056) (0.084) (0.025)
Theta Pre 14.85 5.81 13.86 6.27 0.466 0.957 0.106
Post 12.97 5.76 15.87 8.85 (0.009) (0.001) (0.045)
Alpha Pre 11.38 4.15 10.46 4.21 0.835 0.673 0.023
Post 10.05 3.40 11.38 5.01 (0.001) (0.003) (0.086)
Beta Pre 9.01 3.78 8.26 3.85 0.017 0.023 0.089
Post 12.05 4.86 8.72 4.74 (0.094) (0.086) (0.049)
Gamma Pre 1.69 0.35 1.74 0.39 0.066 0.139 0.038
Post 1.65 0.30 1.98 0.71 (0.057) (0.037) (0.072)
Alpha/Beta ratio Pre 1.01 0.46 1.06 0.42 0.705 0.634 0.364
Post 1.13 0.47 1.02 0.50 (0.002) (0.004) (0.014)
Theta/Beta ratio Pre 1.66 0.36 1.65 0.31 0.209 0.612 0.301
Post 1.79 0.56 1.61 0.51 (0.027) (0.004) (0.018)
All data are presented as mean and standard deviation (SD). CON control, ITSS intranasal thermal steam spray
As shown in Fig. 5, key changes in EEG components after the intervention demonstrated notable group differences. The wide band power increased by 24.90 ± 38.15% in the CON but decreased by -13.46 ± 33.19% in the ITSS group (Fig. 5A). Alpha power declined by about − 3.81 ± 32.46% in the CON but increased by 14.90 ± 43.56% in the ITSS group (Fig. 5D), and gamma power showed a slight increase of 0.20 ± 19.66% in the CON compared to a 13.71 ± 32.89% increase in the ITSS group (Fig. 5F), all of which resulted in significant differences between the groups. Meanwhile, delta (Fig. 5B), theta (Fig. 5C), and beta powers (Fig. 5E), as well as the ABR (Fig. 5G) and TBR (Fig. 5H), showed changes within each group after the intervention, but no significant differences were observed between the groups.
Influence of the ITSS intervention on sleep factors
As presented in Table 6, the sleep quality component of the PSQI-K showed no significant difference between the two groups prior to the intervention. After the intervention, sleep quality increased in the CON but decreased in the ITSS group, indicating a significant interaction effect. Similar trends were observed in sleep-latency, duration, efficiency, disturbance, and daytime dysfunction, suggesting an overall improvement in sleep quality in the ITSS group. Accordingly, the sum scores of the PSQI-K significantly improved in the ITSS group compared to the CON.
Table 6Comparative results of PSQI-K factors between groups
Groups (G)
CON ITSS p(η²)
Items Time (T) mean SD mean SD G T G×T
Sleep quality Pre 2.07 0.58 2.10 0.55 0.001 0.015 0.001
Post 2.73 0.45 0.97 0.61 (0.526) (0.098) (0.617)
Sleep latency Pre 3.03 1.13 3.10 1.37 0.005 0.183 0.001
Post 3.60 1.30 2.00 1.26 (0.129) (0.031) (0.234)
Sleep duration Pre 1.70 0.60 1.67 0.66 0.028 0.556 0.001
Post 1.97 0.67 1.30 0.79 (0.081) (0.006) (0.195)
Sleep efficiency Pre 2.10 0.84 2.13 0.68 0.001 0.001 0.001
Post 2.36 0.73 0.96 0.93 (0.246) (0.168) (0.333)
Sleep disturbance Pre 2.17 0.70 2.23 0.57 0.001 0.002 0.001
Post 2.37 0.85 1.27 0.78 (0.176) (0.150) (0.291)
Sleep medication Pre 0.13 0.43 0.17 0.53 1.000 0.155 0.155
Post 0.13 0.43 0.10 0.31 0.000 (0.034) (0.034)
Daytime dysfunction Pre 2.37 0.81 2.40 0.72 0.001 0.006 0.001
Post 2.57 0.57 1.40 0.67 (0.301) (0.122) (0.239)
Sum scores of PSQI-K Pre 11.50 1.46 11.70 2.26 0.001 0.001 0.001
Post 13.00 2.04 7.03 2.31 (0.453) (0.292) (0.608)
All data are presented as mean and standard deviation (SD). CON control, ITSS intranasal thermal steam spray, PSQI Pittsburgh Sleep Quality Index, VAS visual analogue scale
As shown in Fig. 6, sleep quality increased by 41.67 ± 43.71% in the CON, whereas it decreased by -48.33 ± 47.82% in the ITSS group (Fig. 6A). Sleep latency also increased by 35.61 ± 84.19% in the CON but decreased by -21.78 ± 86.0% in the ITSS group, showing a significant difference (Fig. 6B). Sleep duration (Fig. 6C), sleep efficiency (Fig. 6D), and sleep disturbance (Fig. 6E) increased by 26.11 ± 55.48%, 56.11 ± 155.52%, and 24.44 ± 72.42%, respectively, in the CON, while decreasing by -25.0 ± 40.29%, -50.89 ± 55.16%, and − 44.45 ± 34.0% in the ITSS group, all indicating significant differences between the two groups. No notable changes were observed in the use of sleep medication (Fig. 6F). However, daytime dysfunction increased by 35.0 ± 87.68% in the CON and decreased by -32.78 ± 41.40% in the ITSS group, revealing a statistically significant difference (Fig. 6G). Finally, the total PSQI-K score increased by 14.64 ± 22.44% in the CON but decreased by -38.90 ± 21.99% in the ITSS group, resulting in a significant difference (Fig. 6H).
Discussion
The principal finding of the present study was that improving the nasal environment through ITSS significantly enhanced subjective and objective indicators of sleep quality. Improvements in respiratory function, ANS regulation, and brain activity appear to represent potential physiological mechanisms underlying these beneficial effects on sleep. Notably, improved nasal environment was associated with stabilization of the ANS and enhanced relaxation, as evidenced by changes in wide band, alpha, and gamma EEG activity in young adults with nasal congestion and irregular sleep patterns. These neurophysiological responses appear to contribute to the observed improvements in sleep quality.
The nasal environment, including factors such as nasal cavity volume and resistance, plays a significant role in the transition from wakefulness to sleep. Just as individuals maintain various postures—such as sitting, reclining, or standing—while awake, they also adopt different positions during sleep. These postural changes, along with stressors or neurological factors that may occur during the day, can influence nasal cavity volume and, consequently, affect sleep quality. In this context, an epidemiological study by Young et al. [38] identified nasal congestion as a risk factor for sleep-disordered breathing. In a subsequent population-based cohort study with a five-year follow-up [39], chronic nocturnal nasal congestion was found to be a significant risk factor for habitual snoring (odds ratio 4.9). Beyond epidemiological findings demonstrating the association between nasal congestion and sleep disorders, several laboratory studies have provided experimental evidence for this relationship. Eckert and Younes [40] experimentally induced nasal obstruction and demonstrated an increase in both sleep apnea and electroencephalographic arousals during sleep. Similarly, Fitzpatrick et al. [41] showed that modulating nasal resistance using irritants led to the induction of apnea and hypopnea during sleep. Collectively, the existing body of research suggests that nasal congestion—regardless of its underlying cause—can be considered a contributing factor to the development of sleep problems. Even within the present study, among the 60 participants, the average duration of nasal congestion was 3.39 ± 0.74 years, while the duration of sleep irregularity associated with sleep disturbances was 3.01 ± 0.77 years. These findings suggest a potential relationship between nasal congestion—such as that caused by rhinitis—and sleep-related problems. Considering that the participants were in their early to mid-20s, this association may indicate the potential for more serious consequences later in life. Although not addressed as a primary outcome in this study, the correlation between nasal congestion and irregular sleep patterns was examined, revealing a statistically significant association (r = 0.308, p = 0.017), suggesting a clear link between nasal congestion and sleep patterns. Additionally, prior to the intervention, the average severity of nasal congestion assessed by VAS among the sixty participants was 4.87 ± 0.97, while the perceived severity of sleep-related problems was 4.71 ± 1.64. These findings further support the notion that nasal congestion is closely associated with subjective sleep difficulties. Although no model has directly explained or demonstrated that changes in nasal resistance can induce sleep problems, considering the Starling resistor model in relation to nasal resistance provides a possible explanation. If a narrowed region within the nasal cavity or any other cause leads to increased nasal resistance, negative pressure may develop downstream of the affected area. This negative pressure could contribute to the collapse of the oropharyngeal region, which lacks skeletal support [42]. Furthermore, during sleep, the muscles comprising the oropharyngeal region are in a more relaxed state compared to wakefulness, making them more susceptible to collapse due to negative pressure [43].
To date, numerous studies have reported that treating nasal congestion can improve the quality of life in patients with sleep problems. Li et al. [44] reported an improvement in patients’ quality of life following nasal surgery. Similarly, Miyazaki et al. [45] conducted a study on 54 obstructive sleep apnea patients using a catheter-based pressure transducer to examine the relationship between nasal congestion and obstructive sleep apnea. Their findings suggested that while nasal congestion itself may not be a primary cause of obstructive sleep apnea, it can act as a contributing factor. Additionally, Löth et al. [46] demonstrated that the use of a nostril dilator increased nasal breathing in snoring patients, leading to improved quality of life. Recently, the ITSS device, developed to alleviate nasal congestion, has been reported to help relieve congestion by delivering warm water to the nasal cavity using jet stream wet technology [17]. However, the underlying mechanisms through which ITSS influences sleep quality remain largely unexplored. Specifically, how ITSS improves respiratory function by enhancing nasal hydration and the perception of nasal openness—and how these changes subsequently affect the ANS, brain activity, and ultimately sleep patterns—has not yet been fully investigated. To address this, the present study investigated the effects of ITSS treatment over an eight-week period. The results showed that nasal congestion severity, as assessed by the VAS, increased by approximately 12% in the CON, whereas the ITSS group experienced a 26% reduction following ITSS treatment. Similarly, sleep condition worsened by around 19% in the CON but improved by about 24% in the ITSS group. These improvements were also reflected in respiratory function: the resting respiratory rate increased by approximately 12% in the CON, whereas it decreased by nearly 9% in the ITSS group. Furthermore, while FEV₁ and PEF showed minimal change or slight decreases in the CON, the ITSS group demonstrated significant increases of about 14% and 24%, respectively, suggesting that the improvement in nasal congestion contributed to enhanced respiratory function. This improvement in respiratory function appeared to contribute to reductions in BP, as evidenced by ANS markers in the ITSS group. Specifically, a decrease in SDNN and an increase in RMSSD were observed, indicating a shift toward parasympathetic nervous dominance. Moreover, HF power, which reflects parasympathetic nervous activity, decreased by approximately 23% in the CON but increased by around 10% in the ITSS group. In contrast, the LF/HF ratio, representing sympathetic nervous activity, increased by about 18% in the CON but decreased by nearly 58% in the ITSS group. These results suggest that the ITSS intervention may have facilitated ANS stabilization and contributed to improved BP regulation. The observed improvements in respiratory function may have contributed to enhanced autonomic regulation by reducing upper airway resistance and improving breathing efficiency [47]. This interpretation is supported by the concurrent improvements in heart rate variability and blood pressure observed in the present study, suggesting a shift toward greater parasympathetic activity and reduced sympathetic dominance. Because autonomic balance plays an important role in sleep regulation [9], these physiological changes may partially explain the improvement in sleep quality following intranasal thermal steam spray.
To date, no research has directly examined the effects of ITSS on nasal congestion relief and brain wave changes during sleep or daytime activities such as working. However, a substantial body of literature has investigated the relationship between nasal congestion, sleep quality, and brain wave activity. Understanding these connections is crucial, as nasal congestion can significantly impact sleep architecture, cognitive function, and overall well-being. Several studies have explored the effects of improving nasal environment on brain wave characteristics and sleep patterns. Walsh et al. [48] reported that nasal expansion led to an increase in delta wave activity, which is closely associated with deep sleep and physical recovery. Delta waves (0.5–4 Hz) play a fundamental role in restorative sleep, facilitating tissue repair, immune function, and overall physiological recovery [49–51]. The enhancement of delta wave activity suggests that nasal expansion could contribute to improved sleep quality and physical restoration. According to the EEG analysis in this study, the delta wave increased by nearly 3.23% in the ITSS group, whereas it significantly decreased by approximately 11% in the sham CON (p = 0.025). This trend appears to be consistent with previous studies; however, no significant interaction effect was observed. Therefore, further in-depth investigations are warranted to elucidate the specific mechanisms underlying these changes. This suggests that intranasal steam spray may help regulate sleep-related brain activity by increasing body temperature and alleviating nasal congestion to some extent. This trend is further supported by the findings in the ITSS group, where alpha wave, related to relaxation and a calm mental state, improved by around 15% after the ITSS intervention (interaction effect p = 0.023). Moreover, gamma wave, which is closely linked to stress, anxiety, and cognitive processing, increased by around 14% (interaction effect p = 0.038). Meanwhile, wide band mean power typically ranges between 20 and 40 µV² in a normal resting state. In this study, the CON showed a 25% increase from 29.16 ± 12.08 µV² at baseline to 33.80 ± 9.76 µV² post-intervention, indicating a shift toward a heightened arousal state. In contrast, the ITSS group exhibited a 13% decrease from 30.33 ± 9.29 µV² to 25.20 ± 9.72 µV², suggesting a transition toward a more relaxed physiological state. These results suggest that ITSS may help reduce psychological stress and alleviate mental tension by moistening and expanding the nasal passages. In relation to this, several previous studies have indicated that theta wave plays a crucial role in the transition between wakefulness and sleep, supporting memory processing and emotional regulation [52]. In other words, an increase in theta wave activity suggests that nasal expansion may facilitate smoother sleep transitions and enhance cognitive processing during sleep. Additionally, alpha wave, which is associated with relaxation, meditation, and the transition to sleep, has been shown to increase after nasal expansion. Since alpha wave activity is often linked to a state of wakeful rest and is considered essential for initiating sleep [53, 54], the observed increase in alpha wave in this study indicates that nasal expansion promotes psychological relaxation and prepares the brain for sleep onset. Furthermore, the findings align with the study by Hammer et al. [55], which reported that gamma wave—frequently activated during REM sleep and associated with high-order cognitive functions such as emotional regulation and problem-solving—increased with nasal expansion. In this study, beta wave activity showed a notable increase in the CON, whereas a relatively smaller increase was observed in the ITSS group. This pattern may suggest that the ITSS group experienced a more stable and calmer psychological state. Supporting this, Pei et al. [52] reported that reduced beta wave, resulting from nasal expansion, contributes to a more relaxed physiological state, potentially mitigating hyperarousal that can hinder sleep onset and maintenance. Similarly, some of research noted that beta activity plays a critical role in motor and sensory regulation, as well as in stabilizing and maintaining sleep by ensuring efficient neural communication during sleep [54]. Ultimately, improved nasal condition induced by ITSS may positively influence beta wave, which is associated with physical stability and improved concentration. However, as both groups in the present study showed increased beta waves with no statistically significant interaction effect, further research is warranted to better understand the underlying mechanisms.
To our knowledge, no studies have directly examined the effects of ITSS on nasal congestion relief and PSQI. However, it is well known that nasal congestion negatively affects sleep quality, and various nasal sprays have been reported to help alleviate this issue. In other words, nasal congestion can cause breathing difficulties during sleep, leading to a decline in sleep condition and quality, which may be reflected in an increased PSQI score. For example, saline sprays are commonly used to rinse the nasal passages, remove allergens, and alleviate dryness inside the nasal cavity [56, 57]. Hermelingmeier et al. [58] highlighted that intranasal saline therapy is a safe, cost-effective, and efficient treatment, as it helps remove mucus, accumulated secretions, and inflammatory cytokines from the nasal passages. Similarly, Fokkens et al. [59] reported that it supports mucociliary clearance and reduces mucosal swelling. As a result, intranasal saline therapy is widely recommended as an adjunct treatment for sinonasal conditions such as rhinosinusitis, rhinitis, and upper respiratory tract infections. The intranasal steam spray used in this study introduces 43 °C water into the nasal cavity, promoting nasal expansion and increasing cranial temperature, which may help induce sleep. Notably, the results of this study showed that the “sleep quality” score on the PSQI-K improved by approximately 48% following ITSS intervention, whereas the sham CON exhibited a deterioration of about 42%. Moreover, in terms of sleep latency—the time taken to fall asleep—the CON showed an increase of approximately 36% after the intervention, whereas the ITSS group exhibited a decreasing trend of about 22%, approaching the critical threshold of falling asleep within 30 min. In addition, regarding the PSQI-K subscales—“sleep duration,” “sleep efficiency”, “sleep disturbances,” and “daytime dysfunction”—the placebo-controlled group showed an increasing trend after the intervention, whereas the ITSS group exhibited significant reductions, indicating an interaction effect. Consequently, the total PSQI-K score related to sleep quality increased by approximately 15% in the CON but decreased by 39% in the ITSS group, approaching the threshold score of 7. Considering the PSQI-K criteria established by Sohn et al. [36], where a score of 8.5 or lower indicates good sleep quality and a score above 8.5 indicates poor sleep quality, these findings strongly suggest that intranasal thermal steam spray has a highly positive impact on sleep quality. Meanwhile, a study using the NOZOVENT nasal dilator in 15 individuals with non-pathological nasal structures reported no significant changes in apnea–hypopnea events or oxygen saturation, with only a limited reduction in snoring episodes during slow-wave sleep [60]. Consistently, a systematic review found that most studies reported no improvement in AHI with external nasal dilators, while minor improvements were observed only with certain internal dilators [61]. Taken together, these findings suggest that the effects of nasal dilators on objective sleep parameters remain inconclusive, underscoring the need for further well-designed studies to establish their clinical significance. Several limitations of the present study should be acknowledged. First, although the study was prospectively designed with an a priori sample size calculation and enrolled the required number of participants according to the study design, the overall sample size remained relatively modest. Moreover, the sample size was estimated for the overall two-group, two-time-point repeated-measures design rather than for an outcome-specific effect estimate. Consequently, the study may not have been adequately powered to detect differences across all secondary and mechanistic outcomes, and these findings should therefore be interpreted as supportive and exploratory. Future trials should prospectively define a single primary outcome and base the sample size calculation on a clinically meaningful expected difference in that outcome. Second, because the participants were limited to young adults in their twenties with nasal congestion and irregular sleep patterns, the generalizability of the findings to broader populations, including older adults and patients with clinically diagnosed nasal or sleep disorders, is limited. Accordingly, future studies should recruit larger and more diverse populations to improve the external validity of the findings. Third, although each outcome measure represented a prespecified physiological or clinical endpoint, multiple statistical analyses were performed across several outcome domains. Therefore, the possibility of type I error inflation cannot be entirely excluded and should be considered when interpreting the results. Finally, the intervention was well tolerated throughout the 8-week study period, with no intervention-related serious adverse events or withdrawals attributable to the use of the temperature-controlled intranasal thermal steam spray. While these findings provide preliminary evidence supporting the short-term safety of the intervention, larger-scale clinical trials with longer follow-up periods are warranted to further establish both its long-term safety and clinical effectiveness.
Conclusions
This study concluded that the application of ITSS enhanced the nasal environment—particularly by alleviating the sensation of nasal congestion—which in turn led to favourable changes in cardiopulmonary function. These physiological improvements may further contribute to better sleep quality by promoting ANS balance and stabilizing brain activity.
Supplementary Information
References
1.Błaszczyk JW Metabolites of life: phosphate Metabolites 2023 13 7 860 37512567 PMC10385453 10.3390/metabo13070860 Błaszczyk JW. Metabolites of life: phosphate. Metabolites. 2023;13(7):860.10.3390/metabo13070860 PMC10385453 37512567
2.Beule AG Physiology and pathophysiology of respiratory mucosa of the nose and the paranasal sinuses GMS Curr Top Otorhinolaryngol Head Neck Surg 2010 9 Doc07 22073111 10.3205/cto000071 PMC3199822 Beule AG. Physiology and pathophysiology of respiratory mucosa of the nose and the paranasal sinuses. GMS Curr Top Otorhinolaryngol Head Neck Surg. 2010;9:Doc07.10.3205/cto000071 PMC3199822 22073111
3.Liang H Hou Y Sun L Li Q Wei H Feng Y Supraglottic jet oxygenation and ventilation for obese patients under intravenous anesthesia during hysteroscopy: a randomized controlled clinical trial BMC Anesthesiol 2019 19 1 151 10.1186/s12871-019-0821-8 31409366 PMC6693218 Liang H, Hou Y, Sun L, Li Q, Wei H, Feng Y. Supraglottic jet oxygenation and ventilation for obese patients under intravenous anesthesia during hysteroscopy: a randomized controlled clinical trial. BMC Anesthesiol. 2019;19(1):151.10.1186/s12871-019-0821-8 PMC6693218 31409366
4.Harvey RJ Roland LT Schlosser RJ Pfaar O Chief Complaint: Nasal Congestion J Allergy Clin Immunol Pract 2024 12 6 1462 71 38677589 10.1016/j.jaip.2024.04.028 Harvey RJ, Roland LT, Schlosser RJ, Pfaar O. Chief Complaint: Nasal Congestion. J Allergy Clin Immunol Pract. 2024;12(6):1462–71.10.1016/j.jaip.2024.04.028 38677589
5.Storms W Allergic rhinitis-induced nasal congestion: its impact on sleep quality Prim Care Respir J 2008 17 1 7 18 10.3132/pcrj.2008.00001 18253678 PMC6619860 Storms W. Allergic rhinitis-induced nasal congestion: its impact on sleep quality. Prim Care Respir J. 2008;17(1):7–18.10.3132/pcrj.2008.00001 PMC6619860 18253678
6.Chirakalwasan N Ruxrungtham K The linkage of allergic rhinitis and obstructive sleep apnea Asian Pac J Allergy Immunol 2014 32 4 276 86 25543037 Chirakalwasan N, Ruxrungtham K. The linkage of allergic rhinitis and obstructive sleep apnea. Asian Pac J Allergy Immunol. 2014;32(4):276–86.25543037
7.Wang Y Song XY Wei SZ Wang HR Zhang WB Li YM Mou YK Ren C Song XC Brain response in allergic rhinitis: profile and proposal J Neurosci Res 2023 101 4 480 91 36564932 10.1002/jnr.25159 Wang Y, Song XY, Wei SZ, Wang HR, Zhang WB, Li YM, Mou YK, Ren C, Song XC. Brain response in allergic rhinitis: profile and proposal. J Neurosci Res. 2023;101(4):480–91.10.1002/jnr.25159 36564932
8.Bisogni V Pengo MF Maiolino G Rossi GP The sympathetic nervous system and catecholamines metabolism in obstructive sleep apnoea J Thorac Dis 2016 8 2 243 54 26904265 PMC4739957 10.3978/j.issn.2072-1439.2015.11.14 Bisogni V, Pengo MF, Maiolino G, Rossi GP. The sympathetic nervous system and catecholamines metabolism in obstructive sleep apnoea. J Thorac Dis. 2016;8(2):243–54.10.3978/j.issn.2072-1439.2015.11.14 PMC4739957 26904265
9.Qin H Fietze I Mazzotti DR Steenbergen N Kraemer JF Glos M Wessel N Song L Penzel T Zhang X Obstructive sleep apnea heterogeneity and autonomic function: a role for heart rate variability in therapy selection and efficacy monitoring J Sleep Res 2024 33 1 e14020 37709966 10.1111/jsr.14020 Qin H, Fietze I, Mazzotti DR, Steenbergen N, Kraemer JF, Glos M, Wessel N, Song L, Penzel T, Zhang X. Obstructive sleep apnea heterogeneity and autonomic function: a role for heart rate variability in therapy selection and efficacy monitoring. J Sleep Res. 2024;33(1):e14020.10.1111/jsr.14020 37709966
10.Watso JC Cuba JN Boutwell SL Moss JE Bowerfind AK Fernandez IM Cassette JM May AM Kirk KF Acute nasal breathing lowers diastolic blood pressure and increases parasympathetic contributions to heart rate variability in young adults Am J Physiol Regul Integr Comp Physiol 2023 325 6 R797 808 37867476 PMC11178300 10.1152/ajpregu.00148.2023 Watso JC, Cuba JN, Boutwell SL, Moss JE, Bowerfind AK, Fernandez IM, Cassette JM, May AM, Kirk KF. Acute nasal breathing lowers diastolic blood pressure and increases parasympathetic contributions to heart rate variability in young adults. Am J Physiol Regul Integr Comp Physiol. 2023;325(6):R797–808.10.1152/ajpregu.00148.2023 PMC11178300 37867476
11.Jaeger E Maurer DJ Wallimann A Kistler W Villiger B Agache I Jutel M Nadeau K Rukhadze M Bonini M Price OJ Akdis CA Villiger M Immunity, inflammation and airway dysfunction in elite cross-country skiers and ice hockey players: a systematic review Scand J Med Sci Sports 2025 35 4 e70046 40223161 PMC11994846 10.1111/sms.70046 Jaeger E, Maurer DJ, Wallimann A, Kistler W, Villiger B, Agache I, Jutel M, Nadeau K, Rukhadze M, Bonini M, Price OJ, Akdis CA, Villiger M. Immunity, inflammation and airway dysfunction in elite cross-country skiers and ice hockey players: a systematic review. Scand J Med Sci Sports. 2025;35(4):e70046.10.1111/sms.70046 PMC11994846 40223161
12.Värendh M Andersson M Bjørnsdottir E Hrubos-Strøm H Johannisson A Arnardottir ES Gislason T Juliusson S Nocturnal nasal obstruction is frequent and reduces sleep quality in patients with obstructive sleep apnea J Sleep Res 2018 27 4 e12631 29105874 10.1111/jsr.12631 PMC5936679 Värendh M, Andersson M, Bjørnsdottir E, Hrubos-Strøm H, Johannisson A, Arnardottir ES, Gislason T, Juliusson S. Nocturnal nasal obstruction is frequent and reduces sleep quality in patients with obstructive sleep apnea. J Sleep Res. 2018;27(4):e12631.10.1111/jsr.12631 PMC5936679 29105874
13.Benninger MS Sindwani R Holy CE Hopkins C Early versus delayed endoscopic sinus surgery in patients with chronic rhinosinusitis: impact on health care utilization Otolaryngol Head Neck Surg 2015 152 3 546 52 25573680 10.1177/0194599814565606 Benninger MS, Sindwani R, Holy CE, Hopkins C. Early versus delayed endoscopic sinus surgery in patients with chronic rhinosinusitis: impact on health care utilization. Otolaryngol Head Neck Surg. 2015;152(3):546–52.10.1177/0194599814565606 25573680
14.Corey JP Houser SM Ng BA Nasal congestion: a review of its etiology, evaluation, and treatment Ear Nose Throat J 2000 79 9 690 3 11011488 10.1177/014556130007900908 Corey JP, Houser SM, Ng BA. Nasal congestion: a review of its etiology, evaluation, and treatment. Ear Nose Throat J. 2000;79(9):690–3.11011488
15.Moubayed SP Most SP Evaluation and management of the nasal airway Clin Plast Surg 2022 49 1 23 31 34782137 10.1016/j.cps.2021.08.001 Moubayed SP, Most SP. Evaluation and management of the nasal airway. Clin Plast Surg. 2022;49(1):23–31.10.1016/j.cps.2021.08.001 34782137
16.Rudmik L Hoy M Schlosser RJ Harvey RJ Welch KC Lund V Smith TL Topical therapies in the management of chronic rhinosinusitis: an evidence-based review with recommendations Int Forum Allergy Rhinol 2013 3 4 281 98 23044832 10.1002/alr.21096 Rudmik L, Hoy M, Schlosser RJ, Harvey RJ, Welch KC, Lund V, Smith TL. Topical therapies in the management of chronic rhinosinusitis: an evidence-based review with recommendations. Int Forum Allergy Rhinol. 2013;3(4):281–98.10.1002/alr.21096 23044832
17.Thieme U Müller K Bergmann C Bock B Wurzer-Materna N Shahab T Zeman F Eberhardt Y Huppertz G Koller M Meiser P Randomised trial on performance, safety and clinical benefit of hyaluronic acid, hyaluronic acid plus dexpanthenol and isotonic saline nasal sprays in patients suffering from dry nose symptoms Auris Nasus Larynx 2020 47 3 425 34 32067777 10.1016/j.anl.2020.01.008 Thieme U, Müller K, Bergmann C, Bock B, Wurzer-Materna N, Shahab T, Zeman F, Eberhardt Y, Huppertz G, Koller M, Meiser P. Randomised trial on performance, safety and clinical benefit of hyaluronic acid, hyaluronic acid plus dexpanthenol and isotonic saline nasal sprays in patients suffering from dry nose symptoms. Auris Nasus Larynx. 2020;47(3):425–34.10.1016/j.anl.2020.01.008 32067777
18.World Medical AssociationWorld Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects JAMA 2013 310 20 2191 4 10.1001/jama.2013.281053 24141714 World Medical Association. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA. 2013;310(20):2191–4.10.1001/jama.2013.281053 24141714
19.Hopewell S Chan AW Collins GS Hróbjartsson A Moher D Schulz KF Tunn R Aggarwal R Berkwits M Berlin JA Bhandari N Butcher NJ Campbell MK Chidebe RCW Elbourne D Farmer A Fergusson DA Golub RM Goodman SN Hoffmann TC Ioannidis JPA Kahan BC Knowles RL Lamb SE Lewis S Loder E Offringa M Ravaud P Richards DP Rockhold FW Schriger DL Siegfried NL Staniszewska S Taylor RS Thabane L Torgerson D Vohra S White IR Boutron I CONSORT 2025 statement: updated guideline for reporting randomised trials BMJ 2025 389 e081123 40228833 PMC11995449 10.1136/bmj-2024-081123 Hopewell S, Chan AW, Collins GS, Hróbjartsson A, Moher D, Schulz KF, Tunn R, Aggarwal R, Berkwits M, Berlin JA, Bhandari N, Butcher NJ, Campbell MK, Chidebe RCW, Elbourne D, Farmer A, Fergusson DA, Golub RM, Goodman SN, Hoffmann TC, Ioannidis JPA, Kahan BC, Knowles RL, Lamb SE, Lewis S, Loder E, Offringa M, Ravaud P, Richards DP, Rockhold FW, Schriger DL, Siegfried NL, Staniszewska S, Taylor RS, Thabane L, Torgerson D, Vohra S, White IR, Boutron I. CONSORT 2025 statement: updated guideline for reporting randomised trials. BMJ. 2025;389:e081123.
20.Xing X Yang X Chen J Wang J Zhang B Zhao Y Wang S Multimorbidity, healthy lifestyle, and the risk of cognitive impairment in Chinese older adults: a longitudinal cohort study BMC Public Health 2024 24 1 46 10.1186/s12889-023-17551-1 38166903 PMC10762941 Xing X, Yang X, Chen J, Wang J, Zhang B, Zhao Y, Wang S. Multimorbidity, healthy lifestyle, and the risk of cognitive impairment in Chinese older adults: a longitudinal cohort study. BMC Public Health. 2024;24(1):46.10.1186/s12889-023-17551-1 PMC10762941 38166903
21.Kang H Sample size determination and power analysis using the G*Power software J Educ Eval Health Prof 2021 18 17 34325496 PMC8441096 10.3352/jeehp.2021.18.17 Kang H. Sample size determination and power analysis using the G*Power software. J Educ Eval Health Prof. 2021;18:17.10.3352/jeehp.2021.18.17 PMC8441096 34325496
22.Park S Kim YC Jee YS Plank exercise improves respiratory capacity through positive changes in body composition, abdominis function, and autonomic nerves’ activities Eur J Sport Sci 2024 24 330 40 10.1002/ejsc.12086 Park S, Kim YC, Jee YS. Plank exercise improves respiratory capacity through positive changes in body composition, abdominis function, and autonomic nerves’ activities. Eur J Sport Sci. 2024;24:330–40.
23.Cheng HL. A simple, Easy-to-Use Spreadsheet for Automatic Scoring of the International Physical Activity Questionnaire (IPAQ) Short Form. 2016. Available online: https://www.researchgate.net/publication/310953872. accessed on 6 April 2025.
24.Gelardi M Porro G Sterlicchio B Quaranta N Ciprandi G Italian Study Group on Snoring. Internal nasal dilatator (Nas-Air®) in patients who snore J Biol Regul Homeost Agents 2018 32 5 1267 73 30334424 Gelardi M, Porro G, Sterlicchio B, Quaranta N, Ciprandi G. Italian Study Group on Snoring. Internal nasal dilatator (Nas-Air®) in patients who snore. J Biol Regul Homeost Agents. 2018;32(5):1267–73.30334424
25.Sutbeyaz ST Koseoglu F Inan L Coskun O Respiratory muscle training improves cardiopulmonary function and exercise tolerance in subjects with subacute stroke: a randomized controlled trial Clin Rehabil 2010 24 3 240 50 20156979 10.1177/0269215509358932 Sutbeyaz ST, Koseoglu F, Inan L, Coskun O. Respiratory muscle training improves cardiopulmonary function and exercise tolerance in subjects with subacute stroke: a randomized controlled trial. Clin Rehabil. 2010;24(3):240–50.10.1177/0269215509358932 20156979
26.Brosschot JF Van Dijk E Thayer JF Daily worry is related to low heart rate variability during waking and the subsequent nocturnal sleep period Int J Psychophysiol 2007 63 1 39 47 17020787 10.1016/j.ijpsycho.2006.07.016 Brosschot JF, Van Dijk E, Thayer JF. Daily worry is related to low heart rate variability during waking and the subsequent nocturnal sleep period. Int J Psychophysiol. 2007;63(1):39–47.10.1016/j.ijpsycho.2006.07.016 17020787
27.Burton AR Rahman K Kadota Y Lloyd A Vollmer-Conna U Reduced heart rate variability predicts poor sleep quality in a case-control study of chronic fatigue syndrome Exp Brain Res 2010 204 1 71 8 10.1007/s00221-010-2296-1 20502886 Burton AR, Rahman K, Kadota Y, Lloyd A, Vollmer-Conna U. Reduced heart rate variability predicts poor sleep quality in a case-control study of chronic fatigue syndrome. Exp Brain Res. 2010;204(1):71–8.10.1007/s00221-010-2296-1 20502886
28.Lee D Kwon W Heo J Park JY Associations between heart rate variability and brain activity during a working memory task: a preliminary electroencephalogram study on depression and anxiety disorder Brain Sci 2022 12 2 172 35203935 PMC8870686 10.3390/brainsci12020172 Lee D, Kwon W, Heo J, Park JY. Associations between heart rate variability and brain activity during a working memory task: a preliminary electroencephalogram study on depression and anxiety disorder. Brain Sci. 2022;12(2):172.10.3390/brainsci12020172 PMC8870686 35203935
29.Christov II Daskalov IK Filtering of electromyogram artifacts from the electrocardiogram Med Eng Phys 1999 21 10 731 6 10717553 10.1016/S1350-4533(99)00098-3 Christov II, Daskalov IK. Filtering of electromyogram artifacts from the electrocardiogram. Med Eng Phys. 1999;21(10):731–6.10.1016/s1350-4533(99)00098-3 10717553
30.Sammito S Böckelmann I Reference values for time- and frequency-domain heart rate variability measures Heart Rhythm 2016 13 6 1309 16 26883166 10.1016/j.hrthm.2016.02.006 Sammito S, Böckelmann I. Reference values for time- and frequency-domain heart rate variability measures. Heart Rhythm. 2016;13(6):1309–16.10.1016/j.hrthm.2016.02.006 26883166
31.Barbieri R Matten EC Alabi AA Brown EN A point-process model of human heartbeat intervals: new definitions of heart rate and heart rate variability Am J Physiol Heart Circ Physiol 2005 288 1 H424 35 15374824 10.1152/ajpheart.00482.2003 Barbieri R, Matten EC, Alabi AA, Brown EN. A point-process model of human heartbeat intervals: new definitions of heart rate and heart rate variability. Am J Physiol Heart Circ Physiol. 2005;288(1):H424–35.10.1152/ajpheart.00482.2003 15374824
32.Binnie CD Prior PF Electroencephalography J Neurol Neurosurg Psychiatry 1994 57 11 1308 19 7964803 PMC1073178 10.1136/jnnp.57.11.1308 Binnie CD, Prior PF, Electroencephalography. J Neurol Neurosurg Psychiatry. 1994;57(11):1308–19.10.1136/jnnp.57.11.1308 PMC1073178 7964803
33.Müller-Putz GR Electroencephalogr Handb Clin Neurol 2020 168 249 62 10.1016/B978-0-444-63934-9.00018-4 32164856 Müller-Putz GR. Electroencephalogr Handb Clin Neurol. 2020;168:249–62.10.1016/B978-0-444-63934-9.00018-4 32164856
34.Amin HU Mumtaz W Subhani AR Saad MNM Malik AS Classification of EEG Signals Based on Pattern Recognition Approach Front Comput Neurosci 2017 11 103 29209190 PMC5702353 10.3389/fncom.2017.00103 Amin HU, Mumtaz W, Subhani AR, Saad MNM, Malik AS. Classification of EEG Signals Based on Pattern Recognition Approach. Front Comput Neurosci. 2017;11:103.10.3389/fncom.2017.00103 PMC5702353 29209190
35.Buysse DJ Reynolds CF 3rdMonk TH Berman SR Kupfer DJ The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research Psychiatry Res 1989 28 2 193 213 2748771 10.1016/0165-1781(89)90047-4 Buysse DJ, Reynolds CF 3rd, Monk TH, Berman SR, Kupfer DJ. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 1989;28(2):193–213.10.1016/0165-1781(89)90047-4 2748771
36.Sohn SI Kim DH Lee MY Cho YW The reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index Sleep Breath 2012 16 3 803 12 10.1007/s11325-011-0579-9 21901299 Sohn SI, Kim DH, Lee MY, Cho YW. The reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index. Sleep Breath. 2012;16(3):803–12.10.1007/s11325-011-0579-9 21901299
37.Fritz CO Morris PE Richler JJ Effect size estimates: current use, calculations, and interpretation J Exp Psychol Gen 2012 141 1 2 18 21823805 10.1037/a0024338 Fritz CO, Morris PE, Richler JJ. Effect size estimates: current use, calculations, and interpretation. J Exp Psychol Gen. 2012;141(1):2–18.10.1037/a0024338 21823805
38.Young T Finn L Kim H Nasal obstruction as a risk factor for sleep-disordered breathing. The University of Wisconsin Sleep and Respiratory Research Group J Allergy Clin Immunol 1997 99 2 S757 62 9042068 10.1016/S0091-6749(97)70124-6 Young T, Finn L, Kim H. Nasal obstruction as a risk factor for sleep-disordered breathing. The University of Wisconsin Sleep and Respiratory Research Group. J Allergy Clin Immunol. 1997;99(2):S757–62.10.1016/s0091-6749(97)70124-6 9042068
39.Young T Finn L Palta M Chronic nasal congestion at night is a risk factor for snoring in a population-based cohort study Arch Intern Med 2001 161 12 1514 9 11427099 10.1001/archinte.161.12.1514 Young T, Finn L, Palta M. Chronic nasal congestion at night is a risk factor for snoring in a population-based cohort study. Arch Intern Med. 2001;161(12):1514–9.10.1001/archinte.161.12.1514 11427099
40.Eckert DJ Younes MK Arousal from sleep: implications for obstructive sleep apnea pathogenesis and treatment J Appl Physiol (1985) 2014 116 3 302 13 23990246 10.1152/japplphysiol.00649.2013 Eckert DJ, Younes MK. Arousal from sleep: implications for obstructive sleep apnea pathogenesis and treatment. J Appl Physiol (1985). 2014;116(3):302–13.10.1152/japplphysiol.00649.2013 23990246
41.Fitzpatrick MF McLean H Urton AM Tan A O’Donnell D Driver HS Effect of nasal or oral breathing route on upper airway resistance during sleep Eur Respir J 2003 22 5 827 32 14621092 10.1183/09031936.03.00047903 Fitzpatrick MF, McLean H, Urton AM, Tan A, O’Donnell D, Driver HS. Effect of nasal or oral breathing route on upper airway resistance during sleep. Eur Respir J. 2003;22(5):827–32.10.1183/09031936.03.00047903 14621092
42.Isono S Obesity and obstructive sleep apnoea: mechanisms for increased collapsibility of the passive pharyngeal airway Respirology 2012 17 1 32 42 22023094 10.1111/j.1440-1843.2011.02093.x Isono S. Obesity and obstructive sleep apnoea: mechanisms for increased collapsibility of the passive pharyngeal airway. Respirology. 2012;17(1):32–42.10.1111/j.1440-1843.2011.02093.x 22023094
43.Oliven R Cohen G Somri M Schwartz AR Oliven A Relationship between the activity of the genioglossus, other peri-pharyngeal muscles and flow mechanics during wakefulness and sleep in patients with OSA and healthy subjects Respir Physiol Neurobiol 2020 274 103362 31866501 10.1016/j.resp.2019.103362 PMC7422939 Oliven R, Cohen G, Somri M, Schwartz AR, Oliven A. Relationship between the activity of the genioglossus, other peri-pharyngeal muscles and flow mechanics during wakefulness and sleep in patients with OSA and healthy subjects. Respir Physiol Neurobiol. 2020;274:103362.10.1016/j.resp.2019.103362 PMC7422939 31866501
44.Li HY Lin Y Chen NH Lee LA Fang TJ Wang PC Improvement in quality of life after nasal surgery alone for patients with obstructive sleep apnea and nasal obstruction Arch Otolaryngol Head Neck Surg 2008 134 4 429 33 18427011 10.1001/archotol.134.4.429 Li HY, Lin Y, Chen NH, Lee LA, Fang TJ, Wang PC. Improvement in quality of life after nasal surgery alone for patients with obstructive sleep apnea and nasal obstruction. Arch Otolaryngol Head Neck Surg. 2008;134(4):429–33.10.1001/archotol.134.4.429 18427011
45.Miyazaki S Itasaka Y Ishikawa K Togawa K Influence of nasal obstruction on obstructive sleep apnea Acta Otolaryngol Suppl 1998 537 43 6 9870648 10.1080/00016489850182341 Miyazaki S, Itasaka Y, Ishikawa K, Togawa K. Influence of nasal obstruction on obstructive sleep apnea. Acta Otolaryngol Suppl. 1998;537:43–6.10.1080/00016489850182341 9870648
46.Löth S Petruson B Wirén L Wilhelmsen L Better quality of life when nasal breathing of snoring men is improved at night Arch Otolaryngol Head Neck Surg 1999 125 1 64 7 9932590 10.1001/archotol.125.1.64 Löth S, Petruson B, Wirén L, Wilhelmsen L. Better quality of life when nasal breathing of snoring men is improved at night. Arch Otolaryngol Head Neck Surg. 1999;125(1):64–7.10.1001/archotol.125.1.64 9932590
47.Courtney R Breathing retraining in sleep apnoea: a review of approaches and potential mechanisms Sleep Breath 2020 24 4 1315 25 10.1007/s11325-020-02013-4 31940122 Courtney R. Breathing retraining in sleep apnoea: a review of approaches and potential mechanisms. Sleep Breath. 2020;24(4):1315–25.10.1007/s11325-020-02013-4 31940122
48.Walsh JK Hall-Porter JM Griffin KS Dodson ER Forst EH Curry DT Eisenstein RD Schweitzer PK Enhancing slow wave sleep with sodium oxybate reduces the behavioral and physiological impact of sleep loss Sleep 2010 33 9 1217 25 20857869 PMC2938863 10.1093/sleep/33.9.1217 Walsh JK, Hall-Porter JM, Griffin KS, Dodson ER, Forst EH, Curry DT, Eisenstein RD, Schweitzer PK. Enhancing slow wave sleep with sodium oxybate reduces the behavioral and physiological impact of sleep loss. Sleep. 2010;33(9):1217–25.10.1093/sleep/33.9.1217 PMC2938863 20857869
49.Desai D Momin A Hirpara P Jha H Thaker R Patel J Exploring the role of circadian rhythms in sleep and recovery: a review article Cureus 2024 16 6 e61568 38962617 PMC11221196 10.7759/cureus.61568 Desai D, Momin A, Hirpara P, Jha H, Thaker R, Patel J. Exploring the role of circadian rhythms in sleep and recovery: a review article. Cureus. 2024;16(6):e61568.10.7759/cureus.61568 PMC11221196 38962617
50.Jee YS Relationship between sleep and exercise in the physical health J Exerc Rehabil 2024 20 5 145 39502110 PMC11532398 10.12965/jer.2448420.210 Jee YS. Relationship between sleep and exercise in the physical health. J Exerc Rehabil. 2024;20(5):145.10.12965/jer.2448420.210 PMC11532398 39502110
51.Yoo KS Motion prediction using brain waves based on artificial intelligence deep learning recurrent neural network J Exerc Rehabil 2023 19 4 219 27 37662525 PMC10468292 10.12965/jer.2346242.121 Yoo KS. Motion prediction using brain waves based on artificial intelligence deep learning recurrent neural network. J Exerc Rehabil. 2023;19(4):219–27.10.12965/jer.2346242.121 PMC10468292 37662525
52.Pei S Chen J Lu J Yao L Zhang N Exploring the physiological response differences of β-caryophyllene, linalool and citral inhalation and their anxiolytic potential Heliyon 2024 10 19 e38941 39430514 PMC11490826 10.1016/j.heliyon.2024.e38941 Pei S, Chen J, Lu J, Yao L, Zhang N. Exploring the physiological response differences of β-caryophyllene, linalool and citral inhalation and their anxiolytic potential. Heliyon. 2024;10(19):e38941.10.1016/j.heliyon.2024.e38941 PMC11490826 39430514
53.Zelano C Jiang H Zhou G Arora N Schuele S Rosenow J Gottfried JA Nasal respiration entrains human limbic oscillations and modulates cognitive function J Neurosci 2016 36 49 12448 67 27927961 PMC5148230 10.1523/JNEUROSCI.2586-16.2016 Zelano C, Jiang H, Zhou G, Arora N, Schuele S, Rosenow J, Gottfried JA. Nasal respiration entrains human limbic oscillations and modulates cognitive function. J Neurosci. 2016;36(49):12448–67.10.1523/JNEUROSCI.2586-16.2016 PMC5148230 27927961
54.Rezaei M Mohammadi H Khazaie H Alpha-wave characteristics in psychophysiological insomnia J Med Signals Sens 2019 9 4 259 66 31737555 PMC6839435 10.4103/jmss.JMSS_51_18 Rezaei M, Mohammadi H, Khazaie H. Alpha-wave characteristics in psychophysiological insomnia. J Med Signals Sens. 2019;9(4):259–66.10.4103/jmss.JMSS_51_18 PMC6839435 31737555
55.Hammer M Schwale C Brankačk J Draguhn A Tort ABL Theta-gamma coupling during REM sleep depends on breathing rate Sleep 2021 44 12 zsab189 34297128 10.1093/sleep/zsab189 Hammer M, Schwale C, Brankačk J, Draguhn A, Tort ABL. Theta-gamma coupling during REM sleep depends on breathing rate. Sleep. 2021;44(12):zsab189.10.1093/sleep/zsab189 34297128
56.Chitsuthipakorn W Kanjanawasee D Hoang MP Seresirikachorn K Snidvongs K Optimal device and regimen of nasal saline treatment for sinonasal diseases: Systematic Review OTO Open 2022 6 2 2473974X221105277 35720767 PMC9201324 10.1177/2473974X221105277 Chitsuthipakorn W, Kanjanawasee D, Hoang MP, Seresirikachorn K, Snidvongs K. Optimal device and regimen of nasal saline treatment for sinonasal diseases: Systematic Review. OTO Open. 2022;6(2):2473974X221105277.10.1177/2473974X221105277 PMC9201324 35720767
57.Tano L Tano K A daily nasal spray with saline prevents symptoms of rhinitis Acta Otolaryngol 2004 124 9 1059 62 15513550 10.1080/00016480410017657 Tano L, Tano K. A daily nasal spray with saline prevents symptoms of rhinitis. Acta Otolaryngol. 2004;124(9):1059–62.10.1080/00016480410017657 15513550
58.Hermelingmeier KE Weber RK Hellmich M Heubach CP Mösges R Nasal irrigation as an adjunctive treatment in allergic rhinitis: a systematic review and meta-analysis Am J Rhinol Allergy 2012 26 5 e119 25 23168142 PMC3904042 10.2500/ajra.2012.26.3787 Hermelingmeier KE, Weber RK, Hellmich M, Heubach CP, Mösges R. Nasal irrigation as an adjunctive treatment in allergic rhinitis: a systematic review and meta-analysis. Am J Rhinol Allergy. 2012;26(5):e119–25.10.2500/ajra.2012.26.3787 PMC3904042 23168142
59.Fokkens WJ Lund VJ Hopkins C European position paper on rhinosinusitis and nasal polyps 2020 Rhinology 2020 58 Suppl S29 1 464 32077450 10.4193/Rhin20.600 Fokkens WJ, Lund VJ, Hopkins C, et al. European position paper on rhinosinusitis and nasal polyps 2020. Rhinology. 2020;58(Suppl S29):1–464.10.4193/Rhin20.600 32077450
60.Hoffstein V Mateika S Metes A Effect of nasal dilation on snoring and apneas during different stages of sleep Sleep 1993 16 4 360 5 8141871 10.1093/sleep/16.4.360 Hoffstein V, Mateika S, Metes A. Effect of nasal dilation on snoring and apneas during different stages of sleep. Sleep. 1993;16(4):360–5.10.1093/sleep/16.4.360 8141871
61.Camacho M Malu OO Kram YA Nigam G Riaz M Song SA Tolisano AM Kushida CA Nasal Dilators (Breathe Right Strips and NoZovent) for Snoring and OSA: A Systematic Review and Meta-Analysis Pulm Med 2016 2016 4841310 28070421 PMC5187471 10.1155/2016/4841310 Camacho M, Malu OO, Kram YA, Nigam G, Riaz M, Song SA, Tolisano AM, Kushida CA. Nasal Dilators (Breathe Right Strips and NoZovent) for Snoring and OSA: A Systematic Review and Meta-Analysis. Pulm Med. 2016;2016:4841310.10.1155/2016/4841310 PMC5187471 28070421
Come citare questo studio
Jaehoon Kim, Jaehoon Hwang, Kyungryul Chung, Youngsoo Jin, Yong-Seok Jee. (2026). A randomized controlled trial investigating the effect of thermal steam spray on nasal condition, neurological function, and sleep quality in young adults with nasal congestion and irregular sleep patterns.. BMC pulmonary medicine. DOI: 10.1186/s12890-026-04585-5
Consulta la pubblicazione originale ↗